Descargar Imprimir esta página

Bosch GLM 120 C Professional Manual Original página 29

Ocultar thumbs Ver también para GLM 120 C Professional:

Publicidad

OBJ_BUCH-3181-006.book Page 29 Thursday, April 12, 2018 9:20 AM
Once the final measurement is complete, the
09.06.2017
13:20:23
result is displayed for the distance "X" you
60º
3.624
m
searched for in the result line a. The individual
2.456
m
measured values are in the measured value
4.872
m
4.356 m
lines h.
Wall Surface Measurement (see figure F)
The wall surface measurement is used to determine the sum
of several individual surfaces with a common height.
In the illustrated example, the total area of several walls
should be determined, which have the same ceiling height H,
but different lengths L.
Select the wall surface measurement
Measure the ceiling height H as with a length measurement.
The measured value is displayed in the top measured-value
line. The laser remains switched on.
Then measure the length L
09.06.2017
13:20:23
surface is automatically calculated and dis-
0.0º
2.500
m
played in the result line a. The last length meas-
3.899
m
ured value is in the bottom measured-value line
12.558
m
31.395 m
2
h. The laser remains switched on.
Now measure the length L
of the second wall.The individual
2
measured value displayed in the measured-value line h is add-
ed to the length L
. The sum of the two lengths (displayed in
1
the middle measured-value line h) is multiplied by the saved
height H. The total surface value is displayed in the result line
a.
You can measure any number of lengths L
tomatically added and multiplied by the height H.
The requirement for a correct area calculation is that the first
measured length (for example the ceiling height H) is identical
for all sub-areas.
Stake out Function (see figure G)
The stake out function repeatedly measures a defined length
(distance). These lengths can be transferred to a surface, for
example to enable material to be cut into pieces of equal
lengths or to install stud walls in a drywall construction. The
minimum adjustable length is 0,1 m, the maximum adjustable
length is 50 m.
Note: The distance from the marking is shown in the display
in the marking function. The reference is not the edge of the
measuring tool.
Select the stake out function
Use button 4 [+] or button 11 [–] to set the required length.
Begin the stake out function by pressing the measuring button
2 [
] and slowly move away from the starting point.
The measuring tool continuously measures the
distance to the starting point. The defined
0.81x
0.500m
length and the current measured value are
0.483
m
thereby displayed. The lower or upper arrow
displays the shortest distance to the next or last
1
marking.
Note: When carrying out a continuous measurement, you can
also set a measured value as a defined length by pressing and
holding the measuring button 2 [
Bosch Power Tools
Red arrows or red text indicate the actual value when the ref-
erence is outside of the display.
Gradient Measurement/Digital Spirit Level
Select the inclination measurement/digital spirit level
The measuring tool automatically switches between two
states.
.
of the first wall. The
1
The bottom of the measuring tool is used as the reference lev-
el for the digital spirit level.
measuring tool has been tipped too heavily to the side.
Memory Functions
The value or end result of each completed measurement is au-
, which will be au-
X
tomatically saved.
Tip: When the camera is switched on, the photo is saved auto-
matically, together with the measuring result. The following
information is printed on the photo:
– Measuring result
– Individual measurements (required to determine the
– Measuring function used
– Reference
– Date and time
– Tilt angle (only with spirit level switched on).
If the photo is intended to be used for documentation purpos-
es and transferred via micro USB cable, we recommend disa-
bling the zoom function.
When the measuring tool is connected to an end device by mi-
.
cro USB cable, a csv file with all saved measured values is ad-
ditionally created.
Memory Value Display
A maximum of 50 values can be retrieved (measured values
or photos with measured values).
Select the memory function using soft key 12 [
09.06.2017
13:20:23
].
The left factor specifies how many times the de-
fined length has already been reached. The
green arrows on either side of the display indi-
1x
0.500m
0.500
m
cate the reaching of a length for marking pur-
poses.
The digital spirit level is used to check the hori-
zontal or vertical alignment of an object (e.g.
washing machine, refrigerator, etc.).
1° 2° 3°
When the inclination 3° exceeds, the ball in the
display lights red.
Gradient measurement is used to measure a
slope or incline (e.g. of stairs, railings, when fit-
ting furniture, laying pipes, etc.).
88.0°
The left-hand side of the measuring tool serves
as the reference level for grade measurement. If
the display flashes during measurement, the
measuring result)
The number of the memory value is shown at
4
4
the top of the display, the corresponding mem-
30º
48.873
m
ory value and the corresponding measuring
56.335
m
function are shown at the bottom.
35.5
º
32.852 m
Press button 4 [+] to browse forwards through
the saved values.
English | 29
.
].
1 609 92A 4F4 | (12.4.18)

Publicidad