Descargar Imprimir esta página

Bosch GLM 120 C Professional Manual Original página 30

Ocultar thumbs Ver también para GLM 120 C Professional:

Publicidad

OBJ_BUCH-3181-006.book Page 30 Thursday, April 12, 2018 9:20 AM
30 | English
Press button 11 [–] to browse backwards through the saved
values.
If there is no value available in the memory, "0.000" is shown
at the bottom of the display and "0" at the top.
The oldest value is located in position 1 in the memory, while
the newest value is in position 50 (when 50 memory values
are available). When a further value is saved, the oldest value
in the memory is always deleted.
Deleting the Memory
To open the memory, press soft key 12 [
content of the memory, then press soft key 3 [
times as required.
To delete all values stored in the memory, the "
from the "settings" menu can also be used. Then confirm by
pressing soft key 12 [
].
Formatting the Memory
The USB memory can be reformatted (e.g. in the event of stor-
age problems). To do so, select the "
"settings" menu and confirm by pressing soft key 12 [
Formatting deletes all data stored in the memory. The USB
memory must not be formatted using other devices (e.g.
external PC).
Adding/Subtracting Values
Measured values or end results can be added or subtracted.
Adding Values
The following example describes the addition of areas:
Measure an area as described in section "Area Measurement",
see page 28.
Press the button 4 [+]. The calculated area and
09.06.2017
13:20:23
the symbol "+" will be displayed.
0.0º
51.300
m
2
Press the measuring button 2 [
3.749
m
2
other area measurement. Measure the area as
55.049 m
2
described in section "Area Measurement", see
+
page 28. Once the second measurement is
completed, the result of the second area measurement is dis-
played below.To show the end result, press the measurement
button 2 [
] once more.
Note: With a length measurement, the end result is displayed
immediately.
Subtracting Values
To subtract values, press button 11 [–]. The subsequent
steps are the same as for "Adding Values".
Deleting Measured Values
Briefly pressing the On/Off/Delete button 9 [
the last measured value in all measuring functions.
Bluetooth® Interface
Data Transmission to other Devices
The measuring tool is equipped with a Bluetooth® module,
which enables data transmission via radio technology to cer-
tain mobile terminals/devices with a Bluetooth® interface
(e.g., smartphones, tablets).
1 609 92A 4F4 | (12.4.18)
For information on the necessary system requirements for a
Bluetooth® connection, please refer to the Bosch website at
www.bosch-pt.com
 Further information can be found on the Bosch product
page.
For data transmission via Bluetooth®, time delays between
mobile terminal/device and measuring tool may occur. This
can be possible due to the distance between both devices or
the object being measured.
Activating the Bluetooth® Interface for Data Transmission
]. To delete the
to a Mobile Terminal/Device
]as many
The Bluetooth® interface is activated in the settings. To acti-
vate the Bluetooth® signal, press button 4 [+]. Ensure that the
" function
Bluetooth® interface is activated on your mobile end device.
The special Bosch "Measuring Master" app is available to ex-
tend the range of functions of the mobile end device and to
make data easier to process. You can download this from the
store for your end device type.
" function from the
The connection between mobile end device and measuring
].
tool is established after the Bosch application has started. If
multiple active measuring tools are found, select the appro-
priate measuring tool using the serial number. You can find
the serial number 15 on your measuring tool's type plate.
The connection status, as well as the active connection (f),
are shown in the display 1 of the measuring tool.
Deactivating the Bluetooth® Interface
The Bluetooth® connection is deactivated in the settings. To
deactivate the Bluetooth® signal, press button 11 [–] or
switch off the measuring tool.
USB Port
Data Transmission via USB Interface
] to start an-
Data can be transferred from the measuring tool to certain de-
vices with a USB port (e.g. computer, notebook) via its micro
USB connection.
Connect the measuring tool to your computer or notebook us-
ing the micro USB cable. The operating system on your com-
puter or notebook will automatically recognise the measuring
tool as a drive.
Note: As soon as the measuring tool is connected to a com-
puter or notebook via the micro USB cable, the lithium ion
battery is charged. The charge duration varies depending on
the charging current.
Working Advice
 Further information can be found on the Bosch product
] will delete
page.
 The measuring tool is equipped with a radio interface.
Local operating restrictions, e.g. in airplanes or hospi-
tals, are to be observed.
General Information
The reception lens 20, the laser beam output 18 and the cam-
era 19 must not be covered during measurement.