EN
described in the section describing the cover dismantling. Check that the drive cover is correctly fi tted and that all cover clips are
correctly locked. If it is found that there is a need to replace the drive belt, contact the manufacturer's authorised service centre.
Cleaning the air fi lter
The air fi lter prevents dust and dirt from being drawn into the compressor. The air fi lter becomes dirty, depending on the condi-
tions and operation time of the compressor. Check the soiling status of the fi lter once a month and, if it needs cleaning, clean or
replace the fi lter at least every 50 hours of the compressor operation. A clogged inlet fi lter can severely limit the compressor's
performance and damage the device. It is forbidden to use the compressor without a correctly fi tted air fi lter. Contaminants that
enter the compressor with the air can damage it.
In the devices with the catalogue numbers YT-23300 and YT-23305, unscrew the fi lter by hand counterclockwise, remove the
fi xing screw from the air fi lter housing (XIII), open the housing, and pull the fi lter out of the housing. Clean the fi lter in a soapy water
solution, rinse in water, and dry thoroughly. Place the fi lter in the housing, assemble the two parts of the housing, and screw in the
fi xing screw. Screw the air fi lter clockwise by hand into the air fi lter opening. Ensure that the air fi lter is fi tted correctly.
In the devices with the catalogue numbers YT-23310 and YT-23320, remove the air fi lter from the compressor body using a span-
ner by unscrewing the fi xing screws (XIV). Open the housing and pull the fi lter out of the housing. Clean the fi lter in a soapy water
solution, rinse in water, and dry thoroughly. Place the fi lter in the housing, assemble the two parts of the housing, and fasten the
air fi lter to the compressor body with screws. Ensure that the air fi lter is fi tted correctly.
STORAGE AND TRANSPORT
Transport the device by grasping it by the handle or the base. In the case of transporting it by the means of transport, the com-
pressor must be secured against movement. Only transport and store the device when turned off , disconnected from the power
supply, and with the air tank empty. Store the device in closed well-ventilated rooms. During storage and transport, the device
should not be exposed to direct sunlight, heat sources and precipitation. The storage place should protect the device from access
by unauthorised persons, especially children. Do not place anything on the device.