Problem
Dies or punch guides
cannot be screwed
tight.
Unable to change
gears.
Power tool is stuck in
the workpiece.
Electric tool does not
switch on.
5.1 Replace the power cable
The power cable may only be re-
placed by the manufacturer or its contract
workshops to prevent safety hazards.
For TRUMPF service addresses, see:
www.trumpf.com
5.2 Replace carbon brushes
If the carbon brushes are worn, the
motor stops.
Have carbon brushes checked by a tech-
u
nician and replaced.
Cause
Screws of die or
punch guide are bro-
ken.
Gear blocked.
Punch is broken.
Die screw is broken.
Power tool switched
off when pulling back.
Power tool switched
off when cutting and
cannot be pulled back.
Power cable is defec-
tive.
Carbon brushes are
worn.
Translation of the original operator's manual
Remedy
u
Turning out broken screws
u
Turning eccentric shaft and changing gear
[} 322].
O
u
Changing punches
Checking/replacing wearing parts
u
[} 320].
K
Turn eccentric shaft with the hexagon
u
wrench until the punch is at the top dead
point.
Pull power tool out of the workpiece.
u
u
Remove dies.
Turn eccentric shaft with the hexagon
u
wrench until the punch is at the top dead
point.
Pull power tool out of the workpiece.
u
Re-mount the dies.
u
Replace the power cable [} 21].
u
Replace carbon brushes [} 21].
u
6 Repair
Service, changing, and inspection of power
tools must be done properly.
The safety regulations according to DIN
VDE, CEE, AFNOR, and other regulations
valid in individual countries must be adhered
to.
If a connection line must be replaced, have
this repair done by the manufacturer or its
representative to avoid safety hazards.
[} 322].
N
[} 316].
I
21
EN