Unit description
2.8. Specification table
DC inputs
Recommended power range of the photovoltaic module
MPPT voltage range
Maximum voltage
Nominal input voltage
Start-up voltage
Maximum short circuit current
Maximum current
Inputs with photovoltaic connectors
MPPT number
AC output
Rated power
Apparent maximum power
(1)
Maximum output current
Rated voltage
Voltage range
(2)
Frequency
Type of grid
Adjustable power factor
Efficiency
Maximum efficiency
Euroefficiency
General information
Cooling system
Night consumption
Operating temperature
Relative humidity (without condensation)
Protection class
Markings
Acoustic emissions
Maximum altitude of the installation
Weight
Dimensions (height x width x depth)
Safety and electromagnetic compatibility regulations
Grid connection regulations
In Spain, in accordance with Spanish law, the maximum active power is the same as the nominal power.
(1)
output frequency may vary depending on the different grid codes.
ACL2012IQM01_ - Installation and Operation Manual
10TL M2
10.3 ~ 15 kWp
2*20 A
2*15 A
2 (1/1)
10 kW
11,2 kVA
3*17 A
260 V ~ 510 V (adjustable)
Nominal power
Yes.
97.8%
97.2%
Natural ventilation
< 30 dB
17.2 kg
460 x 398 x 190 mm
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-11, EN 62109-1,
EN 50549-1, NTS SEPE 2.1 type A, UNE 217001, UNE 217002, CEI 0-16 (including Allegato N), CEI 0-21
(including Allegato B), IEC 61727, IEC 62116, VDE-AR-N 4105
15TL M2
20TL M2
15.5 ~ 22.5 kWp
20.6 ~ 30 kWp
160 ~ 1000 V
1100 V
620 V
180 V
20 A + 2*20 A
2*20 A + 2*20 A
15 A + 2*15 A
2*15 A + 2*15 A
3 (1/2)
4 (2/2)
2
15 kW
20 kW
16,7 kVA
22 kVA
3*25.3 A
3*33.7 A
400 V
50 / 60 Hz
TT, TN
> 0.99 (0.8 LD - 0.8 LG)
97.8%
98%
97.4%
97.5%
Forced ventilation
<10W
-25 ºC ~ 60 ºC
0 ~ 100%
IP66
CE
< 45 dB
4000 m
19.1 kg
20.5 kg
EN 62109-2a
The voltage range and
(2)
Ingeteam
EN
ES
FR
IT
PT
13