Descargar Imprimir esta página

GE DPVH890 Manual Del Propietario E Instalación página 23

Profile secadoras
Ocultar thumbs Ver también para DPVH890:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Instructions
CONNECTING
DRYER USING 3-WIRE
CONNECTION
If required,by
localcode,
install external
ground(not
provided)to
grounded
metal, cold
water pipe,
or other
established
ground
determined
by a qualified
electrician.
GreenGround
Ground
Strain
Screw
Strap
Relief
Hot Wire Bracket
Screws
Cover
Neutral
Wire
(white)
_]
3/4" UL
Recognized
Strain Relief
3 #10AWG minimumcopper
conductorsor 120/240V30Apower
supplycordkit marked for usewith
dryersandprovidedwith closed loop
or spadeterminalswith upturnedends
(not supplied)
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer's circuit fuse at the electrical
box.
2. Be sure the dryer cord is unplugged
from the
well receptacle.
3. Remove the power cord cover located at the
lower beck.
4. Install 3/4-in. UL-recognized
strain relief to power
cord entry hole. Bring power cord through
strain
relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws
of the terminal
block (marked L1 and L2).
B. Connect the neutral (white)line
to the center
of the terminal
block (marked N).
6. Be sure ground strop is connected
to neutral
(center) terminal of block and to green ground
screw on cabinet rear. Tighten oil terminal
block
screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
WARNING - NEVER
LEAVETNE
COVER OFF OF THE TERMINAL BLOCK.
23

Publicidad

loading

Este manual también es adecuado para:

Upvh890