1. Hazard area, 1 m.
3 Flat work surface capable of
supporting load.
2.4 Safety provisions
•
The electronic systems switch off automatically if the ambient temperature rises above 70ºC.
•
When heating in temperature mode, the heater switches off if no 1°C temperature increase is
measured during a time pre-set by the manufacturer.
•
The coil of the heater is equipped with a temperature monitor. If the coil becomes too hot, the
heating process is switched off entirely.
•
Models with a swivel arm are equipped with a safety positioning cam.
An induction heater operates by means of a magnetic field. At a distance of 1 metre, the magnetic
field has been reduced to such an extent that it is below the applicable standard
of 0.5mT.
WARNING!
Failure to observe the following warnings could create a risk of death
or serious injury.
•
It is forbidden for persons with active medical aids to be in the immediate vicinity of
the unit when it is in operation. The generated electromagnetic field may influence the
proper function of such medical aids.
•
For this reason, persons with passive implants are recommended not to enter the
immediate vicinity of the induction heater when it is in operation.
12
2 Barrier.
Figure 1
3
1 m
2
1