About the heating modes
Temperature mode
Heating of workpieces to a set temperature; the temperature of the workpiece is monitored during
the whole process.
In the settings menu, it is possible to select a double measurement / ΔT measurement here. T1
(temperature sensor 1) is the main sensor here and is the master for the heating process.
In this mode, one or more temperature sensors have to be used that are positioned on the
workpiece to be heated.
Time mode
Heating of workpieces over time. The heating process is performed for a set time. The workpiece
temperature is not measured or checked.
This mode can be used when you know in advance how long it takes to heat a given workpiece to
a given temperature.
This is the only mode in which the heater can function without temperature sensors being connected.
Time or Temperature mode
Heating of workpieces to a set temperature with the temperature of the workpiece being
monitored during the whole process, or heating over time.
In the settings menu, it is possible to select a double measurement / ΔT measurement here. T1
(temperature sensor 1) is the main sensor here and is the master for the heating process.
In this mode, both the desired workpiece temperature and the desired heating time have to be set.
The heater switches off when one of the two settings (temperature or time) is reached or has elapsed.
In this mode, one or more temperature sensors have to be used that are positioned on the
workpiece to be heated.