or ignorance, are unable to operate the machinery safely must not use it without supervision or
instruction from a responsible person.
Basic knowledge of metalworking especially the correlation of material, tool, feed and speeds.
Please note that local laws and regulations may determine the minimum age of the operator and
restrict the use of this machine!
Put on your personal protective equipment before working on the machine.
Work on electrical components or equipment may only be carried out by a qualified electrician or
under the instruction and supervision of a qualified electrician.
15.3
Safety devices
The machine is equipped with the following safety devices:
15.4
General safety instructions
To avoid malfunctions, damage and health hazards when working with the machine, the following
points must be observed in addition to the general rules for safe working:
Before start-up, check the machine for completeness and function. Only use the machine if
the guards and other non-parting guards required for machining have been fitted, are in
good operating condition and have been properly maintained.
Choose a level, vibration-free, non-slip surface for the installation location.
Ensure sufficient space around the machine!
Ensure sufficient lighting conditions at the workplace to avoid stroboscopic effects.
Ensure a clean working environment.
Only use perfect tools that are free of cracks and other defects (e.g. deformations).
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
A self-locking Emergency Stop button to stop
dangerous movements at any time.
A grinding wheel guard with position switch. The
machine only switches on when the grinding wheel
guard is closed.
Safety catch device. A grinding table guard with position
switch. The machine only switches on when the
grinding table guard is closed.
A cabinet cover with position switch. The machine only
switches on when the protective cover is fitted.
Functional check of the magnet of the magnetic chuck.
The grinding wheel can only be switched on when the
magnetic chuck is activated.
SAFETY