ENGLISH
For appliances installed in banks, an optional
kit is available with the supporting frame and
some trims.
WARNING: The connection must be
made by authorised, skilled personnel, in
accordance with the applicable legal re-
quirements, using appropriate and speci-
fi ed materials. The appliance is supplied
with 400V/3N operating voltage which can
be switched to 230V3.
HAZARD: Before doing any work, turn
off the general power supply.
Connect the appliance to the mains power sup-
ply as follows:
If not already in place, install an automatic
1)
switch-disconnector (A) close to the appli-
ance with thermal magnetic circuit breaker
and residual-current circuit breaker.
Open the hatch (B).
2)
B
10
ELECTRICAL CONNECTION
Undo the screws (C) and remove the lid (D).
3)
Connect the switch-connector (A) to the ter-
4)
minal board (E) of the appliance as shown in
the fi gure and in the wiring diagram at the
end of the manual. Use a fl exible cable with at
least type H07RN-F characteristics and operat-
ing temperature of at least 80°C.
tention to the neutral and earth cable con-
nection.
Tighten the cable gland (F).
5)
Put the lid (D) back in place and fi x it using the
6)
screws (C) once the operation is complete.
Close the hatch (B).
7)
C
A
HANDLING AND INSTALLATION
WARNING: When connecting, pay at-
D
E
F
3443260_inst_GB