7. INSTALLATION
7.2 INSTALLATION GUIDE
• This air conditioner meets the safety and operation standards promulgated by the Nation.
• You need to invite professional air conditioner service and maintenance personnel to install or remove
the air conditioner. Problems may occur and you may suffer losses if non- professionals install the air
conditioner.
• User shall provide the power that meets installation and operation requirements. please refer to name-
plate for details about the voltage for this product. Voltage beyond this scope will affect the normalope-
ration of the air conditioner.
• Separate power point with delay fuse protector or automatic breaker should be used for the airconditioner.
• The air conditioner must be correctly and reliably grounded, or it may cause electric shock or fire.
• Do not switch on the power of the air conditioner before well connecting and carefully checking the tu-
bing and wires.
• The appliance shall not be installed in laundry or bathroom.
• In case necessary, please consult your supply authority for system information.
• The plug shall be accessible after installed the appliance.
• This instruction is subject to change without notice.
Installation of Accessories
• Examine carefully the attached packing list and check whether the accessories are complete.
• Users may need to buy at their own expenses the articles not included in the packing list and may be
needed in installing.
7.3 POSITION FOR INDOOR UNIT
• Away from the place where there is heat source, steam source, leakage of flammable gas and smoke.
• No obstacles near the inlet and outlet, and keep good ventilation.
• Good discharge for water.
• At least 1m away from wireless equipment (such as
TV, radio etc.).
• Mounted on the wall that can bear the weight of the air
conditioner and won't produce noise while unit working.
• The distance between the indoor unit and the floor
should be greater than 2.3m.
• The plug shall be accessible after installing the
appliance.
• Ensure the distance as required in Fig.1.
• The back of the indoor unit should be close to the wall
(Fig.1)
• The all figures are only schematic, and they may be slightly different from the actual appliances you
selected.
60
SPLIT 1X1
EON
At least 15cm
Fig.1