7.14 DRAINAGE
• No need drainage treatment
In regions where become cold in the winter, don't install the drain elbow joint to prevent drain water from
freezing and causing the fan to be damaged. This drainage treatment is not necessary for cooling-only
type air conditioner.
• When need drainage treatment
Please use drain elbow joint (in accessory bag). Outdoor unit should be placed on blocks.
7.15 INSTALLATION FOR THE COVER OF VALVE
• For the whole unit that individual cover of valve is available (refer to packing list), the installing method
is as follow:
• After connecting the connection pipes between indoor and outdoor units followed by the installing me-
thod mentioned above, take out the cover of valve from the accessory bag, and fix it on the side of out-
door unit with three corresponding screws ( inside the accessory bag ).
Elbow joint
Fig.16
Fig.17
USER AND INSTALLATION MANUAL
Chassis
(outdoor)
Drain pipe (buy it by user)
Cover of valve
Screw
7. INSTALLATION