Fig. 15: IP1P Introducer with combined oxy-
gen and temperature probe CC1P1 inserted,
ready for use
AFTER TIGHTENING THE
COMPRESSION CAP, CHECK THE
ASSEMBLY FOR CSF LEAKAGE. IF A
LEAK IS NOTED, HOLD THE WINGS
OF THE BOLT FIRMLY IN ONE HAND
AND TIGHTEN THE COMPRESSION
CAP FURTHER. IF THE CSF LEAKAGE
PERSISTS, REMOVE THE ASSEMBLY IN
ORDER TO PREVENT INFECTION.
P
O
and Temperature Monitoring using
bt
2
the Licox PMOBOX
Prior to measurement the patient bedside
monitor must be zeroed according to
the Licox PMOBOX operations manual.
Please note that temperature will not be
displayed on the bedside monitor.
• Connect
the
temperature probe to the blue monitor
cable REF PMOCAB.
• The smart card is not required. Connect the
Licox PMOBOX and the patient bedside
monitor using NL950-MC-xx cable.
combined
oxygen
P
O
and Temperature Monitoring using
bt
2
the Licox CMP monitor or the Licox P
monitor
• Insert the smart card into the smart card
slot on the front panel of the Licox CMP
monitor or, if using the Licox P
into the smart card slot on the right panel of
the P
O
monitor.
t
2
• Connect the blue leg of the Y-cable
REF BC10PMO to the blue oxygen input
socket of the CMP monitor or the P
monitor and connect the green leg of the
Y-cable to the green input socket of the
CMP monitor or the P
• Connect
REF PMOCAB to the blue leg of the
Y-cable REF BC10PMO.
• Connect
temperature probe to the blue monitor
cable REF PMOCAB.
Normally, reliable p
after a tissue stabilization time of 20 minutes
(when the tissue has stabilized after the
microtrauma of implantation). However, it may
occasionally take up to two hours until the
readings stabilize.
For related information regarding set up and
use please refer to the Licox CMP monitor
operations manual
User's manual
manual.
Safe Removal and Disposal
• Removal of the system should occur in
reverse order of the insertion, i.e. loosen
the compression cap and fittings, remove
the probe, then remove the introducer and
finally the bolt.
DO NOT REMOVE THE BOLT FROM
THE PATIENT WITH THE INTRODUCER
STILL IN PLACE.
• The skin may be closed with a suture or
staples.
The single use components must be
handled as biohazardous material.
Dispose off the single use components
according to the hospital policy.
and
O
monitor.
t
2
the
blue
monitor
the
combined
oxygen
O
readings are available
bt
2
or the Licox P
and/or PMOBOX operations
O
t
2
O
monitor,
t
2
O
t
2
cable
and
O
Monitor
t
2
11

Publicidad

loading