DOORPANEL INSTALLATION
D
oorpanel configuration.
The doorpanel has a microswitch (SW1) and two jumpers
(JP1and JP2) placed on the rear part of the doorpanel.
JP1/JP2
Place both jumpers in COAX position to select
coaxial cable video transmission RG-59
(pages 115 to 116 .
Place both jumpers in TP position to select twisted
pair video signal transmission CAT-5 (pages
117 to 118).
SW1
)
Loads the installation with a communications resistor. For a
proper system operation, activate this resistor only in the
closest doorpanel to the backbone installation or in the
general entrance doorpanel (if exists).
Allows to reset the installer PIN code to the factory default (see
page 83). Use this funtion only in case to forget this code.
With the system switched on, change the switch position to
reset the code and return it to the standby position.
Selects the volume of the doorpanel acknowledgment signals (call
in progress, system busy and door opened).
If after starting the system it´s considered that the volume is too
high, modify the switch position.
Switch to ON in case there´s any UNO monitor or telephone in
the installation. Activate only in the closest doorpanel to the
backbone installation or in the general entrance doorpanel (if
exists).
Switch to OFF when using any digital repeater RD-Plus/Uno.
81