Descargar Imprimir esta página

Kratki PATIO Manual Del Usuario página 36

Estufa exterior de gas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 102
START-UP
Before using the device for the first time, make sure that all the connections to the individual system
components have been made in accordance with the instructions in the manual. Incorrect connection
of the gas control system can result in its damage.
For the first few starts, a specific smell can be detected, lasting up to several hours after use. This phe-
nomenon is related to the burning of paint. Animals may be particularly susceptible to the odours
generated during the paint burning. To speed up this process, it is recommended to warm up the
device to a maximum flame size for several hours.
INSTALLING THE GAS CONTROL SYSTEM
CAUTION!!!
This device and the gas control system can only be installed on factory settings. In the model con-
trolled by the remote control, do not install batteries in the receiver at this stage. Earlier connection
to the power source may damage the electronics of the system.
CAUTION!!!
The components of the gas control system should be installed in accordance with the instructions
in this manual.
Standard gas control system includes, depending on the option: the MertikMaxitrol GV32 or GV60
controller and the B6R-R8U receiver, in which the installed antenna enables wireless remote control.
System components should be installed in their designated areas. Changing their location may expose
the device to damage due to harmful temperatures or flooding.
The device can only work with the automation provided with the device. Connections of individual
components of the system have been made in such a way as to prevent them from being connected
improperly.
The remote control should not be more than 6-8 meters away from the device, in this instance,
after several hours (3-4 hours), the device will shut down automatically.
Connect the reducer to the cylinder making sure that the gaskets are in place (see the diagram above).
If the gaskets are shrivelled or damaged or if any of them are missing, the device cannot be used until
the gaskets are replaced. The valve must always remain/stay in a vertical position after each connec-
tion to the cylinder and throughout the lifetime of the device. Connecting the valve in a different
position results in cutting off the gas supply to the device and thus shutting down the device.
CAUTION!!!
The anti-tilt valve is a safety device against overturning of the device, so that when the device over-
turns, the valve automatically cuts off the gas supply to the controller and this extinguishes the flame.
Fig. 8.
CAUTION!!!
The connection to the gas source should only be made when the heater is off and the cylinder valve
is closed.
CAUTION!!!
It is forbidden to use open fire during the process of installing or connecting the cylinder. Failure to
comply with the above may result in fire, explosion and property damage, personal injury, or even
death.
36

Publicidad

loading