OFF - off
The ON/OFF Knob is in the closed position.
The thermoelectric valve of the control burner is closed (item 1.)
Firing up
The ON/OFF Knob is in the PILOT position and is pressed down. The thermoelectric valve is open
(item 1.), gas flows to the control burner. (Item 2.)
Low flame
The ON/OFF knob is in the ON position.
The Temperature Knob used to adjust the flame is turned in the clockwise direction. Gas flows through
the ON/OFF valve. (Item 3)
48