Descargar Imprimir esta página

MSW Motor Technics MSW-GDOOR-002A Manual De Instrucciones página 85

Accionamiento para puerta corredera

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 285
reduce the power consumption of external accessories under standby mode, the
control board will turn off the power for infrared sensor after entering into
standby mode. When the gate opener is about to operate, it'll supply the power
for accessories. In order to ensure the reliability of the infrared sensor, it is
requested that the control board performs delay detection to the input signal of
infrared sensor. When the gate opener receives the opening/closing signal, it'll
start to work after a certain time (the settled delay time).
Operation instruction:
• Press and hold "PROG" button for 3 sec. to enter into basic menu. The
indicator light L0 will flicker once, then L1 will be steady on.
• Press "PROG" button again for 3 sec. to enter into advanced menu. L0 will
flicker twice, then L1 will be steady on.
• Press "+" button twice to select start-up delay setting. The indicator light L3
will be steady on.
• Press "SET" button once to enter into start-up delay setting. The indicator
lights L1-L3 will show the current setting. (The default is L1).
• Press "+" or "-" button to set the start-up delay time. The indicator lights L1-L3
will show the current setting. (Table 2 Start-up Delay Time).
• Press "SET" button once to save and system will automatically exit. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and go
off.
Indicator light status:
- OFF
- ON
EN
Status meaning

Publicidad