MRSPA4 CONTROL REFERENCE CARD
Diagnostic Messages
Message
Meaning
No message on display.
Power has been cut off to the spa.
Temperature unknown.
"Overheat" - The spa has shut down. One of
the sensors has detected approximately 118°F
(48 °C) at the heater.
"Overheat" - The spa has shut down. One of
the sensors has detected that the spa water is
approximately 110 °F/43 °C.
"Ice" - Potential freeze condition detected.
Spa is shut down. The sensor that is plugged
into the Sensor "A "jack is not working.
Spa is shut down. The sensor that is plugged
into the Sensor "B" jack is not working.
Sensors are out of balance. If alternating with
temperature,it may just be a temporary condi-
tion. If flashing by itself, spa is shut down.
A substantial difference in temperature has
been detected between temperature sensors.
This could indicate a flow problem.
Persistent low flow problems. (Displays on
the fifth occurrence of the "
within 24 hours.) Heater is shut down,but
other spa functions continue to run normally.
Inadequate water detected in heater.
Inadequate water detected in heater.
(Displays on third occurrence of "
sage.) Spa is shut down.
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner 's
manual power connection instructions. Installation must be performed by a licensed electrician and all grounding connec-
tions must be properly installed.
THE CANADIAN SPA COMPANY OWNERS MANUAL
Action Required
The control panel will be disabled until power returns.
Spa settings will be preserved until the next power up.
After the pump has been running for 2 minutes,the tem-
perature will be displayed.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. Once the heater has cooled, reset by
pushing any button. If spa does not reset, shut off the
power to the spa and call your dealer or service organiza-
tion.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. At approximately 107 °F (42 °C), the
spa should automatically reset. If spa does not reset, shut
off the power to the spa and call your dealer or service
organization.
No action required. The pump and blower will automati-
cally activate regardless of spa status.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situ-
ation and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat situ-
ation and disappear when the heater cools.)
If the problem persists, contact your dealer or service
organization.
Check water level in spa. Refill if necessary. If the water
level is okay, make sure the pumps have been primed. If
problem persists, contact your dealer or service organiza-
tion.
Follow action required for "
" message
then back on again to restore heating capability.
Check water level in spa. Refill if necessary.If the water
level is okay,make sure the pumps have been
primed.Press any button to reset.
Follow action required for "
" mes-
automatically reset; you may press any button to reset.
" message. Turn spa off
" message. Spa will not
26