USE AND OPERATION
To carry out this operation, proceed as follows.
IMPORTANT: Before proceeding, al-
low the appliance to cool for 10÷15 min., so
that the oil reaches a temperature between
50÷120°C.
Open the door (A).
1)
Fit the extension (B) onto the tap (C).
2)
Place the container (D) and the fi lter (E) both
3)
available as optionals, underneath the exten-
sion (E).
Turn on the tap (C) to empty the well.
4)
Turn off the tap (C) completion of the opera-
5)
tion.
Close the door (A).
6)
ATTENTION: Do not dump oil in the
environment; dispose of it in accordance
with the laws in force in the country of use.
If the safety thermostat is tripped, the appli-
ance has to be restored to the initial working
conditions as follows.
Allow the oil to cool to 30÷40°C.
1)
Open the door (A).
2)
Press the button (B) of the safety thermostat
3)
tripped to restore the electricity supply.
Close the door (A).
4)
3301300_ut_GB_rev.2