MPL 111 S
GB
7 ANOMALIES, CAUSES AND REMEDIES
On starting, the generator does not run and the starter motor does not emit any signal.
• Check that the thermal switch located on the start unit has not tripped. Check battery connection.
• Check that the emergency stop button is off. If on, turn it to switch it off.
The starter motor turns but the main engine does not start.
• Check that there is fuel in the tank. Fill up.
• Check that the stop solenoid valve is powered. Consult Service Centre.
• Check fuel pump functioning. Consult Service Centre.
The generator switches off during the operating period.
• Check if there is fuel in the tank. Fill up.
• Check if the low oil level protection has been activated; check the level and if low, add the oil necessary to bring
it up to the correct level. There are no warning lights; always carry out a visual inspection.
The engine runs irregularly.
• Check the fuel filter. Replace it.
• Check fuel pump functioning. Consult Service Centre.
• Check the setting of the injectors. Consult Service Centre.
There is high smoke emission from the exhaust.
• Check the air filter. Clean its elements or, if necessary, replace them.
• Check that the oil level does not exceed the MAX notch. Bring it down to the correct level.
Starter battery flat.
• Check the electrolyte level in the battery. Fill up.
• Check the battery charging device. Consult Service Centre.
• Check integrity of the battery.
The generator does not deliver power to the outlets but the voltmeter indicates that voltage is present.
• Check that the differential magnetothermal switch, or a magnetothermal switch, is in the ON position.
The generator does not deliver power to the outlets and the voltmeter does not indicate that voltage is
present.
• Likely alternator fault. Consult a Service Centre.
7.1 H
OW TO ORDER THE SPARE PARTS
In order to ensure a good functioning of the generator, we recommed to use original spare parts only.
The spares can be purchased from the mase authorized assistence network (consult the SERVICE manual
enclosed with the generator).
You can get any futher information contacting the mase central Service.
GB