Hella Gutmann
7.6.8. Level compensation
Activate the level compensation and make settings here.
A level sensor registers the inclination angle of the SEG V and compensates floor unevenness and inclinations of up to 2%
to prevent improper measurements.
7.6.8.1. Executing Manual Level Compensation
Proceed as follows to perform the manual level compensation:
1. Select Settings > Device > Extended in the main menu.
2. Open the selection window under Level compensation with
3. Open the list under Level compensation with
4. Select >Manual<.
If >Manual< is selected, the vertical and horizontal axis level can be manually determined. This compensates uneven-
ness/inclinations in the set-up area of the SEG V and the vehicle.
5. Open the virtual keypad under Pitch angle in % with
6. Enter the desired value and apply.
7. Repeat steps 5 to 7 for the Roll angle in %.
8. Confirm the inputs with
The inputs will be saved automatically.
ð Automatic level compensation continues to remain active in this mode.
7.6.8.2. Executing Automatic Level Compensation
Proceed as follows to do the automatic level compensation:
1. Select Settings > Device > Extended in the main menu.
2. Open the selection window under Level compensation with
3. Open the list under Level compensation with
4. Select >Automatic<.
If >Automatic< is selected, the level of the vertical and horizontal axis adjusts automatically so that any unevenness in
the SEG V setup area is compensated.
Now the device is balanced.
5. Confirm the selection with
The selection will be saved automatically.
7.6.8.3. Switching Off Level Compensation
Proceed as follows to switch off the level compensation:
1. Select Settings > Device > Extended in the main menu.
SEG V
.
. Abort the procedure with
.
. Abort the procedure with
.
.
.
.
.
Device configuration | 7.
109