Pre-Season Check; Submerged Outboard Motor - TOHATSU MD 30B2 Manual Del Propietário

Ocultar thumbs Ver también para MD 30B2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

90
INSPECTION AND MAINTENANCE
ENOM00104-C

4. Pre-season check

The following steps must be taken when
first using the engine after winter storage.
1. Check that the shift and throttle func-
tion properly. (Be sure to turn the pro-
peller shaft when checking the shift
function or else the shift linkage may
be damaged.)
2. Check the electrolyte level, and mea-
sure the voltage and specific gravity of
the battery.
Specific Gravity
at 20°
1.120
1.160
1.210
1.250
1.280
3. Check that the battery is secure and
t h e b a t t e r y c a b l e s a r e p ro p e r l y
installed.
4. Change the engine oil (See page 72).
5. Before starting the engine, disconnect
stop switch lock and crank approxi-
10
mately 3times of 3sec. turning the
starter motor in order to prime the oil
pump.
6. Fill fuel tank completely.
7. Start the engine and warm up the
engine for 3 minutes in the "NEUTRAL"
position.
8. Run the engine for 5 minutes at the
slowest speed.
Terminal Voltage
Charge Condition
(V)
10.5
Fully discharged
11.1
1/4 charged
11.7
1/2 charged
12
3/4 charged
13.2
Fully charged
9. Run the engine for 10 minutes at half
throttle. The oil used for storage inside
the engine will be circulated out to
assure optimum performance.
ENOM00105-A

5. Submerged outboard motor

ENOW00098-0
CAUTION
Do not attempt to start submerged out-
board motor immediately after it is recov-
e r e d , o r e n g i n e c o u l d b e s e v e r e l y
damaged.
After taking your outboard motor out of the
water, immediately take it to your dealer.
The following are the emergency measures
to be taken for a submerged outboard
motor, if you can not take it your dealer
right away.
1. Wash the outboard motor with fresh
water to remove salt or dirt.
2. Remove the engine oil drain screw and
completely drain water and oil from the
engine.
3. Remove the spark plugs, and com-
pletely drain the water from the engine
by pulling emergency starter rope (See
page 40) several times.
Replace oil filter and oil to the correct
level.
The oil and filter may need to be
changed again after running a short
period to get all moisture completely
out of the crankcase.

Publicidad