Descargar Imprimir esta página

Connectors Lay-Out - Cebora 217-01 Manual De Istrucciones

Interfaz analogica robot

Publicidad

Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.
3.4

Connectors lay-out.

Power
supply
input (18 Vac or
24 Vdc polarity
free).
GB
Input - Output
CAN bus Communication line
(4 poles Minifit connectors).
3.4.1
Power supply connector.
3.4.2
Programming connector.
3.300.129-C
Auxiliary services
power
supply
output (24 Vdc).
Programming
connector
Pin
Signal
1(+)
Auxiliary services power supply
2(-)
output.
3
RAI217 power supply input.
4
Pin
1
2
3
4
5
6
7
8
9
10
Plant connections (Phoenix plugs):
Digital Outputs
Digital Outputs
Digital Inputs
Plant connections (Phoenix plugs):
Connector J1.
+24 Vdc, 150 mA max,
18 Vac 50 /60 Hz or
24 Vdc (polarity free).
Connector J8.
Signal
nc
DTR / DSR
TX
RTS / CTS
RX
RTS / CTS
DTR / DSR
nc
Gnd
nc
Rele
Analog Outputs
Analog Inputs
Value