5.4
Operating Mode (bits 0 ÷ 1).
NOTE: If "Quick Stop" is active, neither commands nor command value instructions will be accepted.
Mode 0 (bit 0)
Mode 1 (bit 1)
Reference potential:
5.4.1
Tig mode.
The Tig process is set.
The welding current is set up through the analog input "Welding Current", if the relative dip – switch
DIP3-1 is OFF (par. 3.5.2).
GB
5.4.2
Job mode.
To retrieve stored welding parameters with reference to the number of the "Job" interested.
5.4.3
Parameter Selection Internal mode.
Selecting welding parameters via the Programming Interface of the Robot Control may be difficult and
time consuming especially when programming a "Job". The "Parameter Selection Internal" mode enables
you to select the required welding parameters via the Control Panel. The only signal requested for
welding operations (Arc On) must be supplied from Robot Control.
Internal parameters selection can also be performed during welding.
5.5
Tig Functions (bits 0 ÷ 2).
Terminal
The "Tig Functions" are available when the "Tig" operating mode is selected.
5.5.1
DC / AC.
DC / AC function
DC / AC function
Reference potential:
The DC / AC function is available if the relative dip - switch DIP3-9 is OFF (par. 3.5.2).
5.5.2
Pulsed.
Pulsed function
Pulsed function
Reference potential:
The Pulsed function is available if the relative dip - switch DIP3-10 is OFF (par. 3.5.2).
3.300.129-C
+24 Vdc
+24 Vdc
Gnd
Tig mode
Not used
Job mode
Parameter Selection Internal mode
Connector
9
J10, pin 9
11
J11, pin 1
13
J11, pin 3
-
J1, pin 2
0 Vdc
+24 Vdc
Gnd
0 Vdc
+24 Vdc
Gnd
= J10, pin 5.
= J10, pin 7.
= J1, pin 2.
MODE 1
(bit 1)
0
0
1
1
Signal
+24V
+24V
+24 V
Gnd
= J10, pin 9
= DC welding.
= J10, pin 9
= AC welding.
= J1, pin 2.
= J11, pin 1
= no pulsed welding.
= J11, pin 1
= pulsed welding.
= J1, pin 2.
MODE 0
(bit 0)
0
1
0
1
Tig Function
DC / AC
Pulsed
Non used
Reference potential