WEG Motor Scan Manual General De Instalación Y Operación página 44

Ocultar thumbs Ver también para Motor Scan:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

www.weg.net
Example 3 – The chart of Figure 5.14 shows that the temperature increased gradually. That event may indicate
problems such as:
a) Dust accumulation on the motor,
b) Material accumulation on the fan cover,
c) Bearing in an advanced level of deterioration.
75
65
55
45
35
25
15
1
2
3
Figure 5.14 - Temperature monitoring with gradual temperature change
Example 4 – The chart of Figure 5.15 shows that the surface temperature increases along one day, but it returns
to the initial state. This event, when analyzed together with the ambient temperature, indicates that the motor
did not change its behavior, and the rises in the readings along the day occurred only due to the influence of the
ambient temperature.
75
65
55
45
35
25
15
1
2
3
Figure 5.15 - Temperature monitoring with oscillation in the ambient temperature
44
Manual of Electric Motors
4
5
6
7
Day
Dia
4
5
6
7
Hour
Hora
8
9
10
11
8
9
10
11
Alert
Alerta
Critical
Crítico
Measurements
Medições
Ambient
Ambiente
12
13
Alert
Alerta
Critical
Crítico
Measurements
Medições
Ambient
Ambiente
12
13

Publicidad

Tabla de contenido
loading

Tabla de contenido