fault displayed and the total number of faults present; to the right of these
numbers is an indication of the type of fault displayed.
The + and – keys scroll through the list of faults: pressing the – key goes
back through the log and stops at the oldest fault present, pressing the +
key goes forward in the log and stops at the most recent fault.
The faults are displayed in chronological order starting from the one that
appeared farthest back in time x=1 to the most recent x=y. The maximum
number of faults that can be shown is 64; when that number is reached,
the log starts to overwrite the oldest ones.
This item on the menu displays the list of faults, but does not allow reset.
Reset can be carried out only with the dedicated control from item RF on
the TECHNICAL ASSISTANCE MENU.
The fault log cannot be deleted with a manual reset, by switching off
the appliance, or by resetting the factory values, unless the procedure
described above has been followed.

7.2 - Monitor Menu

From the main menu, by holding down simultaneously for 2 sec the keys
"SET" and "-" (minus), or using the selection menu and pressing + or -,
you can access the MONITOR MENU.
In this menu, by pressing the MODE key, the following values are dis-
played in sequence
7.2.1 - CT: Display contrast
Adjusts the display contrast.
7.2.2 - BK: Display brightness
Adjusts the backlighting of the display on a scale from 0 to 100.
7.2.3 - TK: Backlight switch-on time
Sets the time that the backlight is lit since the last time a key was
pressed.
Values allowed: '0' always off; from 20 sec to 10 min or 'always on'.
When the backlight is off, the first time any key is pressed has the sole
effect of restoring the backlighting.
7.2.4 - LA: Language
Display in one of the following languages:
Italian
English
French
German
Spanish
Dutch
Swedish
Turkish
Slovak
Romanian
7.2.5 - TE: Dissipator temperature display

7.3 - Setpoint Menu

From the main menu, hold down simultaneously the "MODE" and "SET"
keys until "SP" appears on the display (or use the selection menu press-
ing + or -).
The + and – keys allow you respectively to increase and decrease the
plant boosting pressure.
Press SET to leave this menu and return to the main menu.
The range of adjustment is 1-6 bar (14-87 psi).
7.3.1 - SP: Setting the setpoint pressure
Pressure at which the plant is pressurised if there are no active auxiliary
pressure regulating functions.
7.3.2 - Setting the auxiliary pressures
The device has the possibility of varying the setpoint pressure accord-
ing to the status of the inputs, up to 4 auxiliary pressures can be set for
a total of 5 different setpoints. For the electrical connections refer to the
control unit manual; for the software settings see paragraph 7.6.15.3 -
Setting the auxiliary point input function.
If several auxiliary functions associated with several inputs are
active at the same time, the device will set the lowest pressure
of all the active ones.
GB
ENGLISH
89