Table 2. Clearing Error Messages
Error Message
MILKLINE POSITION SW
———————————————
MILK/WASH SWITCH
NOT IN WASH MODE
———————————————
TEMPERATURE
SENSOR FAILURE
———————————————
FAULTY FILL
SWITCH IN
Phase Name—see note 1
———————————————
FILL TIME LIMIT
EXCEEDED IN
Phase Name—see note 1
———————————————
DIVERTED EARLY
DUE TO
TEMPERATURE DROP
———————————————
POWER FAILURE
DURING
Phase Name—see note 1
———————————————
MINOR
POWER FAILURE
———————————————
DETERGENT FILL
TEMPERATURE
NOT REACHED
———————————————
ACID FILL
TEMPERATURE
NOT REACHED
Note:
1. Possible phase names are First Water Rinse, Detergent Phase, Second
Water Rinse, Acid Phase, Third Water Rinse, Sanitize Phase, and Sanitize
Water Rinse.
2. To disable a part's input: Starting at the Main menu, choose OPTIONS,
PARAMETERS (5x), MISCELLANEOUS, INPUTS/OUTPUTS, SENSORS,
then the item in the Sensors menu that relates to the message. Choose

YES or NO (
button) in response to the question that displays. Then, enter
&
your choice (
button).
Guardian II Pipeline Washer
L
——————
Possible Cause
1. Switch was not installed, but will be used.
2. Switch is not activated.
3. Switch is not wired properly.
4. Switch is faulty.
5. Switch will not be used, but was enabled
with a Setup setting.
————————————————————
1. Master Control Panel is not used.
2. Switch is not in correct position.
3. Master Control Panel is not wired
correctly.
4. Switch on control panel is faulty.
————————————————————
1. Sensor was not installed, but will be used.
2. Sensor is open (or shorted).
————————————————————
1. Switch closed before fill started.
2. Switch is faulty.
3. Switch stayed closed.
————————————————————
1. Fill Time Limit was set too low.
2. Water valves are not working properly.
3. Water pump or valves not working.
————————————————————
1. Detergent or Acid Circulation Stop
Temperature was set too high.
2. Detergent or Acid Fill Temperature was
set too low.
3. Water not hot enough.
4. Detergent or Acid Alarm Time was set too
low.
————————————————————
AC power failed for 10 seconds or more.
————————————————————
AC power failed for 2-10 seconds, then
reenergized.
————————————————————
1. Detergent Fill Temperature was set too
low.
2. Detergent Fill Alarm Temperature was set
too high.
3. Water valves are not working properly.
4. Problem with water-supply temperature.
————————————————————
1. Acid Fill Temperature was set too low.
2. Acid Fill Alarm Temperature was set too
high.
3. Water valves are not working properly.
4. Problem with water-supply temperature.
45
——————
Action
1. Disable sensor option per note 2. Install switch
and enable option when time permits.
2. Correct milkline position.
3. Inspect wiring.
4. Replace switch.
5. Disable the part's input per note 2.
——————————————————————
1. Disable Milk/Wash option.
2. Correct switch position.
3. Inspect wiring.
4. Replace switch.
——————————————————————
1. Disable sensor option per note 2. Install switch
and enable option when time permits.
2. Inspect wiring. Replace sensor.
——————————————————————
1. Inspect wiring.
2. Replace switch.
3. Replace switch.
——————————————————————
1. Change setting.
2. Inspect wiring to valves. Use test mode.
3. Inspect water-supply system.
——————————————————————
1. Change setting.
2. Change setting.
3. Check hot water supply.
4. Change setting.
——————————————————————
Inspect AC power panel and wiring.
——————————————————————
Inspect AC power panel and wiring.
——————————————————————
1. Change setting.
2. Change setting.
3. Inspect wiring to valves. Use test mode.
4. Check hot water supply.
——————————————————————
1. Change setting.
2. Change setting.
3. Inspect wiring to valves. Use test mode.
4. Check hot water supply.