- Keep the arm in position and wait for the
acoustic confirmation signal.
- Return the measuring arm to the rest
position.
If the measuring arm is returned to the rest
position after acquiring the data relating
to only one plane or if first the outer plane
data then the inner plate data are acquired,
the "A 23" message is displayed and the
acquired data are not considered.
- Perform a spin
in the version with manual sensor, proceed
as follows:
- Press the
chine for entering distance d1 relative
to the internal side (the distance LED
lights up on the panel).
- bring the end of the measuring arm level
with the plane selected for applying the
internal weight (Fig. 14 for ALU 1P, Fig.
10a for ALU 2P). In Alu 1 P, the centre of
the peg at the end section of the arm is
used as the reference for the centre line
of the weight. In Alu 2 P, the rim edge
is taken as a reference, since the inner
weight is of the conventional clip type.
62
13a
key to prepare the ma-
Pay maximum attention when the end
of the arm is being placed in an area of
the rim free of discontinuity, so that the
weight can be applied in that position.
- Read the internal distance d1 from the
body on the rule.
- Modify the value on the right display by
pressing the
the previously measured distance d1.
- Press the
the machine for entry of the d2 distance
relating to the outer side (the distance
LED lights up on the panel).
- Position the end of the measuring arm on
the plane chosen for the application of
the outer weight (Fig. 14a), as previously
described for the inner side.
- Read the distance d2 from the body on
the rule.
- Modify the value on the right display by
pressing the
the previously measured distance d2.