TROUbLE
SHOOTING
below is a list of faults that may occur and
that the user can solve if the cause is found
among those indicated.
For any other malfunction or fault call in the
technical support centre.
The machine does not switch on
(the displays remain switched off)
No power at the socket.
-Check that mains power is on.
-Check that the workshop electrical system
is working correctly.
The machine plug is defective.
-Check if the plug is working properly and
replace if necessary.
One of the FU1-FU2 fuses of the rear elec-
trical panel has blown.
-Replace the blown fuse.
The values of the dimensions
measured with the automatic
sensor do not match the rated
values of the rims
The sensor was not positioned correctly
when measuring.
-bring the sensor to the position shown in
the manual and follow the instructions in the
WHEEL PARAMETER ENTRY section.
The automatic sensor does not
work
The sensor was not in the rest position at
power on (E 10) and the
geometric wheel parameter entry with the
keypad was pressed, disabling automatic
sensor control.
-Switch off the machine, return the sensors
to the correct position and switch back on.
The sensors have not been calibrated.
➥ Carry out the sensor calibration proce-
dure.
User manual ProLine 650
The wheel fails to spin when the
START button is pressed (the
Check that the guard is not raised (message
"A Cr" displayed).
-Lower the guard.
The wheel balancer provides
unsteady unbalance values
The machine was jolted during the spin.
- Repeat the wheel spin, making sure that
the machine is not subjected to knocks or
vibration while acquisition is in progress.
The machine does not firmly rest on the floor.
- Check that the machine is standing stably.
The wheel is not locked correctly.
-Tighten the locking ring nut firmly.
performed to balance the wheel
The machine was jolted during the spin.
- Repeat the wheel spin, making sure that
the machine is not subjected to knocks or
vibration while acquisition is in progress.
The machine does not firmly rest on the floor.
-Make sure that the floor support is firm.
The wheel is not locked correctly.
-Tighten the locking ring nut firmly.
The machine has not been calibrated cor-
rectly.
-Perform the sensitivity calibration proce-
dure.
The entered geometric data are not correct.
-Make sure that the entered data correspond
to the wheel dimensions and correct them
if necessary.
button for
The "Spare parts" handbook does not au-
thorise users to carry out work on the ma-
chine with the exception of those operations
expressly described in the user manual. It
only enables users to provide the technical
assistance service with precise information
in order to minimise delays.
machine does not start)