NOTES
- On completion of the procedure, remove
the sample weight of 100 gr (3.5 oz).
- Pressing the key
to interrupt the programme at any time.
- THE CALIBRATION PERFORMED IS
VALID FOR ANY TYPE OF WHEEL!
Sensor calibration
This is used to calibrate the automatic
measuring arm potentiometer. This must
be done when requested by the ma-
chine, by displaying the "E4" message, or
when the measured and the actual geo-
metric values of the wheel are different.
- Press the keys until the luminous dot
corresponding to the CAL programme
illuminates.
- Press the
the selection. The "CAL" message will ap-
pear on the left display, and two flashing
"E"s will appear on the right one.
- Mount the template supplied with the
machine on the wheel balancer (A, fig.18)
using the fixing ring nut.
User manual ProLine 650
, it is possible
key twice to confirm
18
- Return the automatic sensor to the rest
position ("completely in").
- Press the
bration in the zero position. The first of
the two flashing "E"s will stop flashing.
- bring the lever of the inner sensor to
rest on the template as shown in figure
19;
- Press the
bration of the potentiometers.
- Return the inner sensor to the rest posi-
tion.
Exit the sensor calibration programme by
pressing the
If the calibration has been performed
successfully, an acoustic consent signal
is emitted. If the message A 20 is dis-
played, this indicates that the position of
the sensor during the calibration phase is
incorrect. Position it correctly, as already
described, and repeat the procedure.
key to perform cali-
19
key to perform cali-
key.
71
UK