Messages On The Displays - Corghi ProLine 650 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 161
MESSAGES ON THE
DISPLAYS
The machine can recognise a certain num-
ber of malfunction conditions and signals
them to the user by visualising the relevant

messages on the displays.

– A – Notice Messages
A 5
Incorrect dimension settings for
an ALU programme. Correct the
set dimensions.
A 7
The machine is temporarily
unable to select the requested
programme.
Perform a wheel spin, then
repeat the request.
A 20
Sensor in incorrect position
during calibration.
bring it to the position indicated
and repeat the calibration.
A 23
Incomplete or incorrect data
entry in ALU P.
Repeat the input correctly.
A 26
Programme available after
selecting one of the following
programmes only: ALU 1P /
ALU 2P / Motorcycle Dynamic /
Motorcycle ALU or if selected
in the Motorcycle Programme
but with the wheel NOT in the
centred position.
A Stp
Wheel stop during the spin
phase.
Wheel movement is not integral
with swinging unit movement:
Check correct wheel tightening.
A Cr
Spin performed with the guard
raised.
Lower the guard to perform the
wheel spin.
– E – Error messages
E 1
Absence of sensitivity calibra-
tion.
User manual ProLine 650
Perform the sensitivity calibra-
tion procedure.
E 2
Error condition on sensitivity
calibration.
Repeat the sensitivity calibra-
tion procedure.
E 4
Sensor calibration error.
The sensor calibration proce-
dure should be carried out.
E 6
Error condition when executing
optimisation programme.
Repeat the procedure from the
beginning.
Err 10
a) Internal distance sensor not
in rest position (completely in)
when the machine is switched
on. Switch off the machine,
return the sensor to the correct
position and switch back on.
b) Failure on the correspon-
ding potentiometer. Press the
key to disable the
sensors and enter the data
using the keypad. Call in the
technical support centre.
E 11
a) Diameter sensor not in rest
(fully out) position when the
machine switched on. Switch
off the machine, return the
sensor to the correct position
and switch back on.
b) Diameter potentiometer
failure. Press the key to dis-
able the sensors and enter
the data manually. Call in the
after-sales service.
E 12
a) Width sensor not in rest (ful-
ly retracted) position when the
machine switched on. Switch
off the machine, return the
sensor to the correct position
and switch back on.
b) Fault on the corresponding
potentiometer. Press the key
to disable the sensors and en-
ter the data using the keypad.
UK
73

Publicidad

Tabla de contenido
loading