7 - Light the burner (see page 11) and turn the
screw (E) until the pressure gauge shows the
pressure recommended in the table of injectors
at the back of the manual.
8 - Check the stability of the flame.
After making the setting, seal the screw with
paint.
Liquid gas
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Unscrew the cap (D).
4 - Remove the adjuster screw (E), the spring (F)
and replace them with the cap (G) (supplied on
request).
5 - Screw the cap (G) fully down.
6 - Restore the initial conditions after completing
the operation.
ADJUSTING BURNER PRIMARY AIR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the locking screw (B).
4 - Set the bush (C) at the distance (D) shown in
the table.
5 - Tighten the screw (B).
6 - Close the door (A).
Gas family
II (G 20/20mbar)
II (G 25/20-25mbar)
II (G 25.1 - G25.3 / 25mbar)
III (G 30-31/29-37mbar)
III (G 30-31/50mbar)
Distance (D)
(mm)
26±1
26±1
26±1
26±1
26±1
- 25 -
9 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
10 - Restore the initial conditions after completing
the operation.