DGE−...−ZR−RF
Rated
coupling
size [mm]
30
40
65
Fig. 13
4. Screw in the locking screws (G) and (H), (but do not tighten yet).
Push the prefitted coupling (K) as far as possible onto the drive shaft.
5. Tightening locking screw (G) (tightening torques see Fig. 13).
6. Fasten the coupling housing (C) with the maximum permitted number of
screws (I).
7. Fasten the connecting flange (L) with the maximum permitted number of
screws to the centering collar of the coupling housing.
8. Push the slide of the DGE−...−ZR−RF into the centre of the stroke (if necessary).
Carr ying out the adjustment
Please read the manual for the controller of your servo motor.
After adjustment of the motor
1. Rotate the drive shaft of the linear axis together with the mounted coupling by
pushing the slide by hand until the locking screw (H) is under a mounting hole
(check with a torch).
2. Fasten the motor block to the connecting flange with four screws.
3. Tighten the locking screw (H) with a hexagon socket wrench (tightening
torques see Fig. 13).
4. Press the plastic plugs supplied onto the mounting holes.
In this way you will avoid dirt on the internal moving parts.
Festo DGE−...−ZR−RF 0405a English
Dimen
Tightening
sion s
torque
[mm]
(screws G
and H)
35
2.9 Nm
66
10.5 Nm
90
25 Nm
s
35