8
Care and maintenance
Recommendation:
S
Return the product to Festo for inspection after every 10,000 kilometres run.
Do not adjust screws or threaded pins for which there are no direct demands
S
for modification in the operating instructions.
Lubricating the roller guide
Lubrication interval: as required, in principle at least after 10.000 km.
S
Note that lubrication must be carried out more frequently:
S
in dusty and dirty environments,
with very short work strokes (running−in at a position).
Lubricate the DGE−...−ZR−RF at the lubrica
S
tion nipples on both sides of the slide.
Oil: e.g. Constant OY 390 from Klüber,
München
Grease gun: see Accessories.
Fitted into restricted spaces:
S Use blast pipe B (axial opening) or C
(radial opening) instead of the stan
dard blast pipe A.
Move through the rated stroke once completely in order to distribute the oil
S
evenly in the interior of the DGE−...−ZR−RF.
At each maintenance procedure:
Check that the slide is set free of play and distortion.
S
If you find something unusual, see the chapter Eliminating faults".
9
Repairs
Faults during operation
Make sure that the DGE−...−ZR−RF is overhauled only by our repair service (es
S
pecially if there is play between the slide and the guide or if the toothed belt is
loose).
In this way you can prevent damage to your axis at a later stage. The repair
procedure requires settings with very fine adjustments.
Festo DGE−...−ZR−RF 0405a English