Festo DGE-25-ZR-RF Instrucciones De Utilizacion página 46

Actuadores lineales
Ocultar thumbs Ver también para DGE-25-ZR-RF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
DGE−...−ZR−RF
3. Push the hardware limit switch for the
relevant end position in the direction of
the switching cam until it responds.
4. Fasten the hardware limit switch directly
at that point.
5. Repeat the last 4 points in the other end
position.
6. Push the slide into the end positions.
You can then check whether the hardware limit switches function correctly and
you can make sure that the switching cams are seated without play.
7. Fasten the safety limit switches between the relevant mechanical end position
(W) and the nearby hardware limit switch (H).
The following specifications apply here:
A braking path of length n remains between the response point of the hard
ware limit switch (H) and the response point of the safety limit switch (S).
The response ranges of the safety limit switch and the hardware limit switch
overlap slightly. When switching on the axis you can thereby avoid unde
fined operating states.
In spite of the fact that the defined end position S is overrun, the safety
limit switches remain actuated until the mechanical end position (W) is
reached.
REF
HW
SS
Fig. 41
46
H
R
x
S
W
n
r
O
REF
= reference point switch
HW
= hardware limit switch
SS
= safety limit switch
W
Fig. 40
O/2
Festo DGE−...−ZR−RF 0405a English
H
h
H
S
W
n
r
O

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dge-40-zr-rfDge-63-zr-rfDge-serieDge-zr-rf serie

Tabla de contenido