Kärcher SB-HDW S 1 Manual De Instrucciones página 99

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 262
SB-HDW S 1 / SB-HDW S 2
Operating Instructions
n Checking of burner setting
fuel pressure
blower pressure
CO2
Temperature exhaust fumes
Loss exhaust fumes
Soot coefficient
In case values measured deviate from above basic settings
the setting of the burner needs to be adjusted.
i
Important!
When finished with examination plant door has to be closed
and burner functioning tested with plant completely closed.
In case the burner becomes extinguished by lack of air the
following measures can be taken:
n Removal of closing plugs from plant floor
n Partial removal of sealings from door sides. Starting from
the bottom sealings should be shortened by 20 to 30 cm.
English
bar
10
mbar
2
%
10...11
°C
190±10
%
max. 10
max. 1
I 5