Start Button Produces No Effect; Some Signals From H Connector Do Not Work - Cebora SYNSTAR 200 M Manual De Servicio

Ocultar thumbs Ver también para SYNSTAR 200 M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

□ Fan (44) starts working.
YES
Correct?
♦ Check wiring between J7 power board (45)
and J1 panel board (48).
♦ Check supply voltages of the power (45) and
panel (48) boards, performing the tests of par.
3.3.1.
ERROR CODE TEST.
□ Upon turning the unit on, after the start-up phase, an
error condition is displayed: a code appears on the dis-
play A to identify the error type.
NO
Correct?
♦ See Error codes, par. 3.4.
COMMANDS AND SIGNALS TEST.
□ After the start-up phase, with knob B it possible to per-
form all of the steps involved in selecting a "Process",
"Mode" and "Programs", as described in the Instruc-
tions Manual.
YES
Correct?
♦ Check the supply voltages of power (45) and
panel (48) boards, performing, if necessary,
the tests of par. 3.3.1.
♦ Make sure that the correct program is
inserted in the panel board (48), performing,
if necessary, the "Firmware Upgrade"
procedure (see par. 2.4).
■ Check wiring between J7 power board (45) and J1
panel board (48).
■ Replace the power (45) and/or panel (48) boards.
3.3.4

Start button produces no effect.

NOTE
The start command may be given to the power source either
through the central adapters C or via the connector H.
The two circuits are parallel connected inside the panel
board (48), so only one of the two signals is enough to start
the power source.
START COMMAND TEST.
□ Panel board (48), terminal J6-A(+) and J6-B(-) = 0 Vdc
with start button pressed, +9 Vdc approximately, with
button released (with button connected to the central
adapters C).
3302316/A
NO
YES
NO
□ Panel board (48), connector J3, terminals 3(+) and 4(-) =
0 Vdc with start button pressed, +9 Vdc approximately,
with button released (with button connected to the
connector H).
YES
Correct?
♦ Check the wiring between J6, panel board
(48), central adapter C and torch button.
♦ Check the wiring between J3, panel board
(48) and connector H.
♦ Check the supply voltages of the panel board
(48), performing, if necessary, the PANEL
BOARD (48) POWER SUPPLY TEST, of
par. 3.3.1.
♦ Replace panel board (48).
■ Check integrity of the components inserted on the start
line between J6 and Q1 on the panel board (48) (see
connectors map, par. 5.5).
■ Replace panel board (48).
3.3.5

Some signals from H connector do not work.

EXTERNAL SIGNALS TEST.
Fig. 3.3.5
□ Connector H, signals as shown in the table, with power
source powered and connector H free (no accessory
connected to H)
1(+) - 8(-)
push-pull motor output
1(+) - 9(-)
spool on gun motor output
2(+) - 3(-)
potentiometer cursor
5(+) - 4(-)
Start command
spool on gun torch inserted
6(+) - 3(-)
recognition signal
push-pull
torch
7(+) - 3(-),
recognition signal
10(+) - 3(-) potentiometer supply
NO
+12 Vdc
approx.(no
loaded voltage,
capacitive
voltage).
+3,3 Vdc
+9 Vdc
+3,3 Vdc
inserted
+3,3 Vdc
+3,3 Vdc
23
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

322