Type (C)
2.1.3.
Select the type of machine shown on the machine name plate. The name plate is on the back side
of the machine.
Speed Unit (D)
2.1.4.
Set the unit to program and display basket speed.
Staph Guard (E)
2.1.5.
Set whether this machine is a Staph Guard pass-through model.
Comm Port (F)
2.1.6.
Set the communications port used by the processor board to communicate with the peripheral
boards. This decision is dependent on machine hardware. See
processor board revision.
Port 3—Choose this value if the processor board is earlier than "Rev G."
Port 1—Choose this value if these conditions are met: (1) The processor board is "Rev G" or
later, (2) The machine software is WUMTCOMB/40049B or later, and (3) The serial link to
the peripheral boards is physically wired to Port 1 on the processor board.
Figure 24: Processor Board Revisions
Revision F Processor Board
.
Tip:
If your machine meets the conditions described in the "Port 1" description above, set configure
decision F = Port 1 to take full advantage of the improved resistance to electrical interference. For
more details on this topic, see
Board".
Drain Code (G)
2.1.7.
Set the time for drain speed between two bath steps and between a bath step and an extract step.
CAUTION 2 : Avoid Machine Damage—Do not select a drain code that provides less time
at drain speed than stated on the machine configuration nameplate.
Chapter 2. How to Configure and Program the Control
Section 4.1. "How to Install and Configure the Rev G Processor
27
Figure 24
for how to identify the
Revision G Processor Board
PELLERIN MILNOR CORPORATION