Injection Time—Number of seconds to inject this chemical.
Signal with Injection—Enable this decision to sound the operator signal and require the operator
to press the Signal Cancel button before the injection begins.
Speed
2.2.10.
Wash Speed (RPM)—Range is 010 RPMs minimum to 038 RPMs maximum
Extract Speed (RPM)—Minimum value is 200 RPMs. Maximum value is determined by
machine model.
Drain Type
2.2.11.
Standard—Basket rotates at approximately 1 G-force for the drain duration. Actual speed is
determined by the configured machine type. The drain valve opens after a distribution delay.
2-Way Wash—Basket rotates both directions at wash speed while draining. The drain valve
opens when the step timer expires.
Do Not Drain—The drain valve remains closed to keep the bath liquor for the next step. Basket
rotation is determined by the following bath step.
Stop with Fill—The basket does not rotate while the machine is filling. The drain valve opens
after a distribution delay.
Stop with Drain—The basket does not rotate while the machine is draining. The drain valve
opens when the step timer expires.
Stop with Fill and Drain—The basket does not rotate during filling and draining. The drain
valve opens when the step timer expires.
RinSave—The basket rotates according to a specific sequence, described below. The drain valve
opens 10 to 15 seconds after the step timer expires.
Supplement 3
1. When the bath ends, the cylinder turns clockwise at wash speed for 8 seconds.
2. Before the drain valve opens, the cylinder accelerates to the standard drain speed for 4
seconds.
3. The drain valve opens and the cylinder turns at standard drain speed for a time determined
by the configured machine type.
4. The cylinder accelerates to RinSave speed for the remainder of the drain sequence.
5. If the next step is an extract step, the cylinder accelerates to the programmed speed. If the
next step is a bath step, the cylinder decelerates to a stop.
Re-Use Drain
2.2.12.
To Sewer—Drain this extract step to the sewer.
Reuse Tank—Drain this extract step to a reuse tank through a secondary drain valve.
How to End
2.2.13.
Stop—The operator signal sounds, and the basket coasts to a stop.
Reversing—The operator signal sounds, and the basket reverses for 20 seconds in each direction
with 3 seconds of dwell time between reversals.
Chapter 2. How to Configure and Program the Control
®
The RinSave
Drain Sequence
35
PELLERIN MILNOR CORPORATION