Chapter 2. How to Configure and Program the Control
Steam Error (H)
2.1.8.
Set the time allowed for the machine to use steam to heat the water to the correct temperature.
Fill Error (I)
2.1.9.
Set the maximum time allowed for the machine to fill to the desired level.
Cooldown Error (J)
2.1.10.
Set the time allowed for the machine to complete a cooldown to a programmed bath temperature.
Extra Water (K)
2.1.11.
Set whether this machine is attached to a third water source.
Reuse Drain (L)
2.1.12.
Set whether this machine has a reuse tank and a second drain valve.
Overhead Tank (M)
2.1.13.
Set whether this machine has an overhead tank.
Flow Meters (N)
2.1.14.
Set whether this machine is equipped with flow meters to measure incoming water.
Tilt Type (O)
2.1.15.
Set the tilt system for this machine:
RPM Control (P)
2.1.16.
Set whether this machine has speed control.
Recirculation (Q)
2.1.17.
Set whether this machine has the equipment required to recirculate bath liquor.
AmpSaver (S)
2.1.18.
Set whether this machine is part of a Milnor
consumption.
Temperature Probe (T)
2.1.19.
Set whether this machine has a temperature sensor. A temperature sensor allows programming a
specific temperature for each bath step.
Electronic Level (U)
2.1.20.
Set whether this machine has electronic level sensing abilities (pressure transducer).
Variable Speed (W)
2.1.21.
Set whether this machine has variable speed abilities.