Installing The Communication Assembly - SMA STP 50-40 Instrucciones Para La Sustitución

Ocultar thumbs Ver también para STP 50-40:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SMA Solar Technology AG
10. Remove the three screws of the communication
assembly (TX20), remove the communication
assembly and dispose of the screws.
5

Installing the Communication Assembly

1. Insert the new communication assembly in the DC Connection Unit.
2. Fasten the communication assembly using the three screws included in the scope of delivery
(TX20, torque: 3.5 Nm ± 0.5 Nm (30.98 in-lb ± 4.43 in-lb)).
3. Insert all plugs into the respective sockets of the communication assembly.
4. If necessary, install the communication modules (see the manual of the communication
module).
5. Attach the enclosure lid before mounting the DC-Connection Unit (see Section 6, page 12).
6. Commission the inverter without integration into the local network (see inverter manual). It can
take up to 15 minutes before the new assembly has synchronized with the inverter. It can also
be that an inverter update is performed.
7. Update the inverter network settings and integrate the inverter into the local network (see
inverter manual).
8. Stick the label provided in the scope of delivery over
the existing label next to the type label.
9. If necessary, reconfigure the communication modules. For this, start the installation wizard via
the user interface of the inverter (see manual of the inverter).
Replacement Manual
5 Installing the Communication Assembly
_
+
_
+
STPxx-US-4x-COM-RM-xx-10
3x
3x
K
I D / P S
P I C / R
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Stp 50-jp-40Stp 50-us-40Stp xx-us-41

Tabla de contenido