Commissioning Movement Profiles - Festo CMFL Instrucciones De Utilizacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
CMFL

Commissioning movement profiles

1. Set the signals of the two control bits 1 and 2. Select the desired movement
profile. The following movement profiles are stored in the CMFL corresponding
to the control signals:
Steuerbit 1
(Control bit 1)
0
1
0
1
Fig. 13
2. Set the START signal to high (1) (grant enable).
The LED is constantly illuminated green and the movement is started.
3. Check whether the ADNE-LAS moves through the complete intended
positioning cycle.
Fig. 14 CMFL execution pattern
Observe the maximum permissible movement frequencies in the operating
instructions of the ADNE-LAS (
In the case of several immediately successive movements, observe the
recommended damping time t
(
Technical data).
36
Steuerbit 2
Movement profile
(Control bit 2)
0
Piston rod extends
0
Piston rod retracts
1
Piston rod first extends and then retracts
1
Piston rod first retracts and then extends
Technical data).