Electrical data

CMFL
Load voltage supply
– Nominal voltage
– Perm. voltage fluctuation
– Nominal current
– Peak current
Controller interface (I/O supply)
– Nominal voltage
– Perm. voltage fluctuation
– Nominal current
– Peak current
– Specification
Protection against electric shock
(protection against direct and indirect contact acc.
to IEC/DIN EN 60204-1)
CE symbol (declaration of conformity)
www.festo.com
Recommended damping time t
For ADNE-...
With load
1)
with load voltage supply 24 VDC/48 VDC
Fig. 18
Festo – CMFL – 1304b English
[V]
24/48
[%]
±5
[A]
3
[A]
4.5/8
[V]
24
[%]
±10
[mA]
100
[mA]
200
Based on IEC 61131-2
By means of PELV circuit
(Protected Extra Low Voltage)
As per EU EMC directive
[ms] between Motion Complete and Start Signal
b
32-25
0 g
15/10
250 g
25/25
500 g
35/65
1)
32-35
40-20
1)
1)
10/10
20/10
1)
1)
25/20
20/15
1)
1)
45/35
35/20
40-45
1)
1)
25/35
1)
1)
25/37.5
1)
1)
40/40