Error Display - Festo CMFL Instrucciones De Utilizacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
CMFL

Error display

LED display
Orange, flashes:
– Single
– Double
Red illuminated
Red, single flashes
Red, double flashing
Red, triple flashing
Red, flashes
four times
Red, flashes
five times
Fig. 16
Festo – CMFL – 1304b English
Category
Possible cause
Warning
Motor temperature above
65 °C
Motor temperature above
70 °C
Error
Motor cable not connected;
broken cable
Error
Motor temperature above
75 °C
Error
Positioning task not
completed in the intended
time window (timeout)
Error
Load voltage outside the
permissible range
Error
General error
Error
Teach procedure could not
be performed
Remedy
Is automatically extinguished
when the motor temperature
falls below 60 °C
De-energise CMFL and
– connect motor
– replace cable
Let motor cool off. Error cannot
be acknowledged over the
Enable input until the motor
temperature falls below 65 °C
(LED then flashes red-orange).
Check whether piston rod is
blocked or if the load to be
moved is too large;
repeat the Teach procedure,
if necessary
Correct load voltage;
repeat the Teach procedure,
if necessary
Send ADNE and CMFL to Festo
– Check set-up
– Repeat Teach procedure
39