Pos: 48 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Restrisiken @ 0\mod_1427723332615_370.docx @ 26639 @ 2 @ 1
2.7
Residual risk
Pos: 49 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Herabfallende Teile Multi @ 4\mod_1449223317742_370.docx @ 54387 @ 3 @ 1
2.7.1
Falling parts
The lifting hooks on the motor are designed for the weight of the
motor. The lifting hooks can break if the complete pump unit is
attached.
Attach the pump unit consisting of motor, pump and filter
housing (where necessary) on both the motor and the pump
sides. See chapter 4.2 on page 20.
Only use hoisting and load-bearing equipment which is
suitable and technically sound.
Do not stand under suspended loads.
Pos: 51 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Rotierende Teile - GSA @ 1\mod_1429096331026_370.docx @ 27892 @ 3 @ 1
2.7.2
Rotating parts
There is a risk of shearing and crushing due to exposed rotating
parts.
Only perform servicing when the pump/unit is not in
operation.
Prior to servicing, ensure the pump/unit cannot be switched
back on.
Immediately after finishing servicing, reattach or reactivate all
protective equipment.
Pos: 52 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Standsicherheit Multi @ 4\mod_1449223352677_370.docx @ 54403 @ 3 @ 1
2.7.3
Stability
Ensure sufficient stability of the pump/unit. There is a danger
of crushing due to tilting or falling over.
Pos: 54 /Technische Dokumentation/Betriebsanleitung/Sicherheit/Restrisiken/Elektrische Energie @ 0\mod_1427779167394_370.docx @ 26692 @ 3 @ 1
2.7.4
Electrical energy
There is an increased risk of electric shock when working on the
electrical system due to the humid environment.
Electrical protective earth conductors which were not installed
correctly can also result in electric shocks, for example oxidation
or cable breakage.
Observe VDE and utility company regulations.
Build swimming pools and their protection according to
DIN VDE 0100-702.
Before working on the electrical system, take the following
measures:
– Disconnect system from the power supply.
04/2016
Safety
EN 11