5.4

Electrical connection

WARNING
Risk of electric shock due to incorrect connections!
Electrical connections must always be carried out by
authorised specialists.
Observe VDE and utility company regulations.
Install swimming pools and their protection according to
DIN VDE 0100-702.
Install a disconnecting device with at least a 3 mm contact
gap per pole to interrupt the power supply.
WARNUNG
Risk of electric shock due to voltage on the housing!
An overload switch which is set correctly must be installed for
pumps with three-phase motors without motor protection. In
doing so, observe the values on the motor name plate.
Protect power supply with a ground fault circuit interrupter,
nominal residual current I
necessary when other devices are being run at the same
time – always according to the local regulations).
Only use suitable pipe types according to regional
regulations.
Adjust minimum diameter of the pipes to accommodate the
motor output and pipe length.
If hazardous situations can occur, provide emergency off
switch according to DIN EN 809. The builder/operator must
make a decision according to this standard.
The use of a frequency converter or a smooth start is
recommended in order to rule out pressure surges on the unit
side.