Faults
Pos: 164 /Technische Dokumentation/Betriebsanleitung/Störung/Multi/Leckage an der Pumpe @ 4\mod_1449582273704_370.docx @ 55449 @ @ 1
Fault: Pump leaks
Possible cause
Screw connection or seal
faulty.
Pos: 166 /Technische Dokumentation/Betriebsanleitung/Störung/Multi/Zu starke Leckage der Gleitringdichtung @ 4\mod_1449582292451_370.docx @ 55465 @ @ 1
Fault: Shaft seal leaks too much
Possible cause
Mechanical seal is worn.
Damage during
disassembly.
Pump is loud.
Pump strained or
vibrations in the pipes.
Pump shaft slipped.
Pos: 167 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
36 EN
Solution
Renew seal between volute
casing and housing lid.
Tighten screw connections.
Solution
Renew mechanical seal.
Renew mechanical seal.
Correct suction conditions.
Adjust pump unit.
Increase the pressure on the
suction discharge.
Check pipe connections and
pump fasteners, if necessary
reduce the pipe bracket
spacing.
Fasten pipes using vibration
reducing materials.
Fix pump shaft. See chapter
8.5.5 on page 45.