SERVICE PROCEDURES
10
GB
SERVICE PROCEDURES
Continued
PUMP ROTOR
(Procedure if Rotor is Binding)
1. Remove upper shell (see page 7).
2. Remove fi lter end cover screws using5/16" nut-driver.
3. Remove fi lter end cover and air fi lters.
4.Remove pump plate screws using 5/16"nut-driver.
5. Remove pump plate.
6. Remove rotor, insert, and blades.
7. Check for debris in pump. If debris is found, blow out with
compressed air.
8.Install insert and rotor.
9. Check gap on rotor. Adjust to .076/.101 mm (.003"/.004") if
needed (see Figure 25).
Note: Rotate rotor one full turn to ensure the gap is .076/.101
mm (.003"/.004") at tightest position. Adjust if needed.
10.Install blades, pump plate, air fi lters and fi lter end cover.
11.Replace fan guard and upper shell.
12.Adjust pump pressure (see page 8).
Note: If rotor is still binding, proceed asfollows.
13.Perform steps 1 through 6 above.
14.Place fi ne grade sandpaper (600 grit) on fl at surface. Sand
rotor lightly in "fi gure 8" motion four times (see Figure 26)
15.Reinstall insert and rotor.
16.Perform steps 10 through 12 above.
H.
G.
F.
A.Blade, B.Pump plate, C.Air intake fi lter, D.Filter end cover,
E.Fan guard, F.Air output fi lter, G.Rotor, H.Insert.
Figure 23 – Rotor location, 35.000 btu/Hr, 64.000 btu/Hr and
70.000 Btu/Hr.
A.
B.
C.
D.
H.
A.Blade, B.Pump plate, C.Air intake fi lter, D.Filter end cover,
E.Fan guard, F.Air output fi lter, G.Rotor, H.Insert.
Figure 24 – Rotor location, 100.000 and 150.000 Btu/Hr.
A.
C.
Figure 25 – Gap adjusting screw locations.
E.
Figure 26 – Sanding rotor.
A.
B.
G.
F.
B.
A.
A. sandpaper
A.
C.
D.
E.
A. gap adjusting
screw
B. .076/.101 mm
(.003"/.004") Gap
Measured With
Feeler Gauge
C. Blade