FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
1 . Fuse or circuit breaker blown .
2 . Loose power line connections to the fan,
3 . Fan Wall Control is OFF .
2. Fan sounds noisy.
1 . Blades not attached to fan .
2 . Loose screws in motor housing .
3 . Screws securing fan blade flanges to
4 . Wire connectors inside switch housing
5 . Screws holding blades to flanges
3. Fan wobbles
1 . Set screw in motor coupler is loose .
excessively.
2 . Set screw in hanger ball/downrod
3 . Screws securing fan blade flanges to
4 . Fan blade flanges not seated properly .
5 . Hanger bracket and/or ceiling outlet
6 . Fan blades out of balance .

15. Troubleshooting

!
PROBABLE CAUSE
or loose switch wire connections in the
switch housing .
motor hub are loose .
rattling .
are loose .
assembly is loose .
motor are loose .
box is not securely fastened .
WARNING
SUGGESTED REMEDY
1 . Check main and branch circuit fuses or circuit
breakers .
2 . Check line wire connections to fan and switch
wire connections in the switch housing .
Make sure main power is turned OFF.
3 . Turn ON Fan Wall Control .
1 . Attach blades to fan before operating .
2 . Check to make sure all screws in motor housing
are snug (not over-tight) .
3 . Check to make sure the screws which attach
the fan flanges to the motor hub are tight .
4 . Check to make sure wire connectors in switch
housing are not rattling against each other or
against the interior wall of the switch housing .
Make sure main power is turned OFF.
5 . Tighten screws securely .
1 . Tighten both set screws securely in the motor
coupler .
2 . Tighten the set screw in the hanger ball/
downrod assembly .
3 . Check to be sure screws which attach the fan
blade flanges to the motor are tight .
4 . Check to be sure the fan blade flanges seat
firmly and uniformly to the surface of the motor .
If flanges are seated incorrectly, loosen the
flange screws and retighten according to the
procedure in the section on "Ceiling Fan
Assembly" .
5 . Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box .
6 . Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation .