12
ERROR CODES
Error management is divided into two categories:
1) Hardware errors [E]. These cannot be reset and require the power source to be restarted. They are displayed
on the screen with a red background.
2) Alarms [W] linked to an external condition that can be reset by the user and does not require the power
source to be restarted.These are displayed on the screen with an amber background.
Code
Type
3
[E]
General fault error detected by
the power source internal slave
board
4
[E]
Error on database
6
[E]
Communication error detected
by master panel board on CAN-
bus
7
[E]
Communication error in CAN2.
8
[E]
Communication error between
master board and motor control
board
9
[E]
Communication error between
Slave board and Master board
10
[E]
Power output nil (I=0A, V=0V)
11
[E]
Overload at output
13
[E]
Login time too long
14
[E]
Undervoltage error detected on
inverter control board.
20
[E]
Interlock signal absent
22
[E]
Hardware key not readable
23
[E]
Earth cable leakage
25
[E]
Excessive primary winding cur-
rent error
26
[E]
Time not set or battery flat
29
[E]
SRS kit Item No 443 not working. Check the connection between power source and SRS kit Item
30
[E]
Output current sensor offset rea-
ding problem
3301065/A
Error Description
Switch the power source off and on. If the problem persists,
contact technical assistance
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Check the connection between CN2 and robot interface.
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Check connection between power source and wire feeder,
manual Item No 5690133 or Robot Item No 1648. Switch the
power source on and off. If the error persists, contact technical
assistance.
With the power source in manual mode, check connection
between power source and wire feeder. In robot mode, check
the connection between power source and remote panel Item
No 452. Switch the power source off and on. If the problem
persists, contact technical assistance
Hardware error, contact technical assistance. Probable break in
inverter circuit of primary winding
Hardware error, contact technical assistance.
Hardware error, contact technical assistance.
Check machine supply voltages. If the problem persists, con-
tact technical assistance.
Switch the power source off and on. If the problem persists,
contact technical assistance
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Probable break in output diodes or primary winding inverter cir-
cuit. Switch the power source on and off. If the error persists,
contact technical assistance.
Switch the power source on and off. If the error persists, con-
tact technical assistance.
No 443. If the problem persists, contact technical assistance.
Switch the power source on and off. If the error persists, con-
tact technical assistance.
Action
107/109